Contactor Data
| Main Part No. | DHC250 | ||
| Contact Data | Contact form | 1H(SPST-NO) | |
| Rated load(Resistive load) | 250A | ||
| Min applicable load (Resistive load) | 1A/12VDC | ||
| Max switch current | 2000A(300VDC)1 time | ||
| Max switch voltage | 1000VDC | ||
| Contact voltage drop(initial) | ≤80mV@250A | ||
| Current carrying capacity(a) | 250A : continued | ||
| 375A:1h | |||
| 500A:20min | |||
| 800A: 30s | |||
| 2000A: 0.6s | |||
| Impact resistance | Stability | Half-sine shock
pulse:11ms |
ON: 196m/s²(> 20G) |
| OFF: 98 m/s²(> 10G) | |||
| Strength | Half-sine shock | 490 m/s²(> 50G) | |
| Vibration resistance | 10Hz~500Hz 49 m/s²(> 5G) | ||
| Product installation mode | Arbitrarily | ||
Coil Data(20℃)
| Coil rated volt. | Pick-up volt. | Release volt. | Max operate volt. | Rated current(±10%) | Rated coil power |
| 12VDC | ≤9VDC | ≥1VDC | 16VDC | Pick-up:2.92A
Hold-in:0.375A |
Pick-up:35W(0.2s Pick-up)
Hold-in:4.5W |
| 24VDC | ≤18VDC | ≥2VDC | 32VDC | Pick-up:1.46A
Hold-in: 0.188A |
Pick-up:35W(0.2s Pick-up)
Hold-in: 4.5W |
Part Numbering System


Shape installation and circuit diagram


Coil lead out mode (Tianhai: 0435308 or Yazaki: 7283-1020)


Note: The main contact connect “+” polarity to the main contact terminal with “1+” mark, and connect “-” polarity to the main contact terminal with “2-” mark.
Current tolerance curve


Note: The above data is tested at 85℃ ambient temperature, Traverse area≥95mm². The data is for reference only, please do not use to select the fuse directly.
Electrical life curve


Pick-up / release voltage curve


The above data are tested by random sampling of coil volt. 12VDC product. The data is for reference only, (test qty:n=3)